Configuring a Persona serial number for the IN120 and IN220 locks - Synergis™ Softwire 11.2

Synergis™ Softwire Integration Guide 11.2

Applies to
Synergis™ Softwire 11.2
Last updated
2023-04-03
Content type
Guides > Integration guides
Language
English
Product
Synergis™ Softwire
Version
11.2

Before you can use passage mode on SARGENT and Corbin Russwin Cx locks IN120 and IN220, they must be configured with a PERSONA serial number.

Procedure

  1. Connect the lock to a workstation, and open the lock configuration file using the LCT tool.
  2. From the Lock Configuration page, click the Settings icon.
  3. Click the Serial Number Setup tab.
  4. Change the Manufacturer and Board Type to Persona.
  5. Apply the changes and follow the on-screen instructions.
    The lock now has a new serial number.
  6. Using LCT, re-apply the configuration to the lock.
  7. If the lock was already added to the Synergis™ unit, do the following:
    1. Delete the lock and re-add it using the new serial number.
    2. Re-configure the door entity hardware with the new lock.