To enable passage mode on doors controlled by Assa Abloy IP locks, you must create a Boolean custom field named PassageMode for either doors or access rules.

Procedure

To enable the passage mode feature per door:

  1. In Config Tool, create a Boolean type custom field for door entities, and name it PassageMode.
    NOTE: You must spell the name exactly as it is written, with capital and lowercase letters.
  2. Open the Area view task.
  3. From the entity browser, select a door, and then click the Custom fields tab.
  4. Select the PassageMode custom field, and then click Apply.
  5. Repeat the previous two steps for all doors on which you want passage mode enabled.

To enable the passage mode feature per access rule:

  1. Log on to your Synergis™ unit using the following URL:
    https://<IP address>/Features/PassageMode/Enabled/Set?value=true, where <IP address> is the IP address of your Synergis™ unit.
  2. Click the link to apply the setting.
  3. Restart your Synergis™ unit.
    The PassageMode custom field for access rules is automatically created in Security Center.
  4. From the Config Tool home page, open the Access control task, and click the Access rules view.
  5. From the entity browser, select an access rule, and then click the Custom fields tab.
  6. Select the PassageMode custom field, and then click Apply.
  7. Repeat the previous two steps for all access rules on which you want passage mode enabled.