After you install the proxy service, you must configure it to connect to the AMAG Symmetry server. You can also change the ports used by the proxy service, and change the polling frequency of different entities.
What you should know
Procedure
-
Open the Amag Symmetry Proxy Configuration Page using
http://localhost:<Port>/config. The default port
value is 1312.
NOTE: If the Amag Symmetry Proxy Configuration Page doesn’t open, ensure that the port number configured in the user.config file and the port number in the proxy configuration file match.
-
Connect the proxy service to the AMAG Symmetry server by configuring the
following fields:
- In the Proxy section:
- Proxy Password
- Create a password to use to connect to the plugin. The proxy service must be configured to use the same credentials as the plugin role.
- In the Amag Symmetry section:
- Host
- The hostname of the AMAG Symmetry server that runs Symmetry XML Open Integration Module.
- Username and Password
- The credentials for a user account in Symmetry SMS. The proxy must be configured to use the same credentials as the plugin role.
NOTE: After establishing the initial connection between the proxy service and the AMAG Symmetry server, the Host, Username, and Password values are saved, and don’t need to be re-entered. - In the Proxy section:
- Click Save in both Proxy and Amag Symmetry sections.
-
In the Amag MultiMAXTxn Database section, connect to the
AMAG SQL Server database by configuring the following fields:
- Server
- Enter the hostname or IP address of the server on which the database resides.
- User ID and password
- Enter the credentials for the AMAG SQL Server
database.NOTE: Connection using Windows authentication is not supported. The credentials of a SQL server user are required.
NOTE: You can configure the AMAG SQL Server to force the encryption of communication between the databases and the Genetec™ Inc. service. - Click Save in the Amag MultiMAXTxn Database section.
- Optional:
Configure the following settings:
Proxy
- Proxy Port
- The configuration proxy service port used by the plugin to host the Amag Symmetry Proxy Configuration Page. The default value is 1312. The changes take effect after restarting the proxy service.
- Symmetry Service Port
- The communication channel port between the plugin and the proxy
service is connected to AMAG Symmetry. The default value is 1313.
The changes take effect after restarting the proxy service.IMPORTANT: The Symmetry Service Port configured in the Amag Symmetry Proxy Configuration Page must match the port used in the plugin role's Properties page.
Amag Symmetry
- Use https
- If you want communication between the proxy and the plugin to happen over an HTTPS connection, select the Use https option. For more information on enabling HTTPS communication, see Enabling a secure HTTPS connection.
- Enable door status retrieval
- If you want Security Center door icons to indicate when a Symmetry
door is open or closed, select the Enable door status
retrieval checkbox. Ensure that the Door
Status on Graphics option is also enabled in Symmetry SMS. IMPORTANT: If, for performance issues, the Door Status on Graphics option is disabled in Symmetry SMS, then you must clear the Enable door status retrieval checkbox in the AMAG Symmetry proxy service, otherwise the proxy service will fail.
- Enable secure communication
- If you want to encrypt communication between the plugin and the proxy using a TLS certificate, select the Enable secure communication option. For more information on enabling secure communication, see Enabling encryption for the AMAG Symmetry plugin.
Polling frequency
- Polling frequency (seconds)
- The proxy service checks for changes to entities, events, and alarms
at regular intervals. The polling frequency sets how long the proxy
waits to start polling after the last set of changes were received.
- The default frequency is 5 seconds. CAUTION:Using the default value might impact performance. Increase or decrease the polling frequency as needed.
- Set Polling Frequency to
0 if you need updates
continuously and the computer that hosts the Symmetry XML Open Integration Module is powerful enough to handle the
load.CAUTION:Using this configuration can cause the AMAG Symmetry system to stop working correctly. It’s best practice to avoid this configuration.
- Set Polling Frequency to -1 to stop checking for updates.
- The default frequency is 5 seconds.
NOTE: Make sure to save your changes. Each section of settings has a separate Save button used to apply the changes made to that section only.