Mapping alarm priorities - To ensure incoming AMAG Symmetry alarms are prioritized correctly in Security Center, map the AMAG alarm priority values to corresponding Security Center priority values. - AMAG Symmetry 3.3 - Plugin and extension guides

AMAG Symmetry Plugin Guide 3.3.1

Product
AMAG Symmetry
Content type
Guides > Plugin and extension guides
Version
3.3
Release
3.3.1
ft:locale
en-US
Last updated
2026-01-12

To ensure incoming AMAG Symmetry alarms are prioritized correctly in Security Center, map the AMAG alarm priority values to corresponding Security Center priority values.

What you should know

AMAG Symmetry supports priority levels from 1 - 999 while Genetec Inc. supports priority levels 1 - 255. When an alarm is triggered, alarm priority levels are retrieved from the AMAG Symmetry server. Edit the Genetec.Plugins.Amag.Symmetry.ProxyService.exe.config file to map the AMAG alarm priority values to corresponding Security Center values.

After an alarm is triggered with a specific priority in Security Center, its priority can’t be altered even if it changes in AMAG Symmetry. The priority is only updated the next time that alarm is triggered.

Procedure

  1. Navigate to the proxy installation folder.
    NOTE: The default location is C:\Program Files (x86)\Genetec\Symmetry Proxy Service.
  2. Open the Genetec.Plugins.Amag.Symmetry.ProxyService.exe.config configuration file.
  3. Change the EnableAlarmPriorityMap value to True.
  4. Configure the AlarmPriorityMap values with your desired alarm priority mappings.
    WARNING: You must map all values. If any values are unmapped, an AMAG alarm priorities {0} left undefined. error appears on the plugin role and all mappings are reverted to the default values.
  5. Save the file.

Example

The following is an example of the default priority mapping:
<?xml version="1.0" encoding="utf-8"?>
<configuration>
  [...]
  <applicationSettings>
    <Genetec.Plugins.Amag.Symmetry.ProxyService.Properties.Settings>
    
      [...]
      
      <setting name="EnableAlarmPriorityMap" serializeAs="String">
        <value>False</value>
      </setting>
      <setting name="AlarmPriorityMap" serializeAs="String">
        <value>1:1, 2:2, 3:3, 4:4, 5:5, 6:6, 7:7, 8:8, 9:9, 10:10, 11:11, 12:12, 13:13, 14:14, 15:15, 16:16, 17:17, 18:18, 19:19, 20:20, 21:21, 22:22, 23:23, 24:24, 25:25, 26:26, 27:27, 28:28, 29:29, 30:30, 31:31, 32:32, 33:33, 34:34, 35:35, 36:36, 37:37, 38:38, 39:39, 40:40, 41:41, 42:42, 43:43, 44:44, 45:45, 46:46, 47:47, 48:48, 49:49, 50:50, 51:51, 52:52, 53:53, 54:54, 55:55, 56:56, 57:57, 58:58, 59:59, 60:60, 61:61, 62:62, 63:63, 64:64, 65:65, 66:66, 67:67, 68:68, 69:69, 70:70, 71:71, 72:72, 73:73, 74:74, 75:75, 76:76, 77:77, 78:78, 79:79, 80:80, 81:81, 82:82, 83:83, 84:84, 85:85, 86:86, 87:87, 88:88, 89:89, 90:90, 91:91, 92:92, 93:93, 94:94, 95:95, 96:96, 97:97, 98:98, 99:99, 100:100, 101:101, 102:102, 103:103, 104:104, 105:105, 106:106, 107:107, 108:108, 109:109, 110:110, 111:111, 112:112, 113:113, 114:114, 115:115, 116:116, 117:117, 118:118, 119:119, 120:120, 121:121, 122:122, 123:123, 124:124, 125:125, 126:126, 127:127, 128:128, 129:129, 130:130, 131:131, 132:132, 133:133, 134:134, 135:135, 136:136, 137:137, 138:138, 139:139, 140:140, 141:141, 142:142, 143:143, 144:144, 145:145, 146:146, 147:147, 148:148, 149:149, 150:150, 151:151, 152:152, 153:153, 154:154, 155:155, 156:156, 157:157, 158:158, 159:159, 160:160, 161:161, 162:162, 163:163, 164:164, 165:165, 166:166, 167:167, 168:168, 169:169, 170:170, 171:171, 172:172, 173:173, 174:174, 175:175, 176:176, 177:177, 178:178, 179:179, 180:180, 181:181, 182:182, 183:183, 184:184, 185:185, 186:186, 187:187, 188:188, 189:189, 190:190, 191:191, 192:192, 193:193, 194:194, 195:195, 196:196, 197:197, 198:198, 199:199, 200:200, 201:201, 202:202, 203:203, 204:204, 205:205, 206:206, 207:207, 208:208, 209:209, 210:210, 211:211, 212:212, 213:213, 214:214, 215:215, 216:216, 217:217, 218:218, 219:219, 220:220, 221:221, 222:222, 223:223, 224:224, 225:225, 226:226, 227:227, 228:228, 229:229, 230:230, 231:231, 232:232, 233:233, 234:234, 235:235, 236:236, 237:237, 238:238, 239:239, 240:240, 241:241, 242:242, 243:243, 244:244, 245:245, 246:246, 247:247, 248:248, 249:249, 250:250, 251:251, 252:252, 253:253, 254:254, 255:255-999</value>
      </setting>
      
      [...]
      
    </Genetec.Plugins.Amag.Symmetry.ProxyService.Properties.Settings>
  </applicationSettings>
  [...]
</configuration>