There are some things you should know when installing or upgrading to Sharp 11.5 SR1.

Please note the following when installing or upgrading to Sharp 11.5 SR1:
  • IMPORTANT: Component updates from Security Center must be performed in a specific order: When using Security Center to update to SharpOS 11.5, you must update the SharpOS components in the following order:
    1. Plate Reader
    2. Update services
    3. Firmware

      The firmware cannot be updated before the Plate Reader, the firmware update will fail.

  • Support for digest authentication: After upgrading a Sharp that was enrolled under the Archiver, if you turn the Refuse Basic Authentication setting ON, the Sharp might disconnect from the Archiver. To reconnect to the Archiver, you must reset the Sharp Password in the Sharp Portal. Note that you can reset to the original password. A new password is not required.