Issue First reported in Hardware affected Description
2434201 13.0 GA SharpV

SharpZ3

When configuring a Sharp unit for FTP communication, the Test connection button always results in a failed test.
Workaround: To verify the configuration, click Send sample.
2433783 13.0 GA SharpZ3 Following a hardware reboot, a Sharp unit can sometimes restart in APIPA mode instead of using DHCP or the fallback IP address.
Workaround: Reboot the Sharp unit again.
2430297 13.0 GA SharpV

SharpZ3

When you enable remote assistance on a Sharp unit, you can click Extend by 1 hour once, but it is not possible to extend remote assistance twice.
Workaround: Disable remote assistance, then enable it again.
2417869 13.0 GA SharpZ3 If the relay state is changed in the second stack's Sharp Portal, its state is not reflected in the first stack's Sharp Portal.