Network cable requirements for SharpV cameras - SharpV | SharpOS 14.2

AutoVu™ SharpV Deployment Guide 14.2

Applies to
SharpV | SharpOS 14.2
Last updated
2023-03-14
Content type
Guides > User guides
Language
English
Product
SharpOS
SharpV
Version
14.2

The SharpV connects to the network using a standard CAT5e network cable (not included). Consult this list of specifications when selecting and preparing the network cable.

Network cable specifications

Hardware Specification
Cable rating CAT5e or higher (special connector provided for IP67 rating)
Shielding Shielded or unshielded
Conductor gauge 24 AWG
Conductor arrangement Straight-through EIA-568A or EIA-568B
Cable diameter The RJ45 connector that is shipped with the system accepts CAT5e cable diameters from 4.8 mm (0.19 in) to 6.7 mm (0.26 in).

The bayonet shell supports cable diameters from 4.5 (0.18 in) to 8 mm (0.31 in).

Cable length Maximum 100 m (330 ft)
Environmental The network cable must be waterproof and UV-resistant, with a temperature rating appropriate for your climate.
PoE++ standard PoE++ (Power over Ethernet) 802.3bt Type 3 40 W
NOTE:
  • Not all hardware that is labeled "PoE++" meets the IEEE 802.3bt standard that is required for use with the SharpV.
  • Ensure that the total power consumption of all hardware connected to the PoE++ source does not exceed the power budget of the PoE++ source. Each SharpV camera must be supplied with 40 W.
  • If the SharpV is supplied with PoE+ or PoE power, it might still operate with limited functionality. For more information, see Troubleshooting: SharpV cannot read plates but Sharp Portal is accessible.

Network cable power

Power can be supplied to the SharpV through the network cable, using PoE++. Power the network cable, using one of the following methods:
  • PoE++ switch or router: Connect a network cable that has a maximum length of 100 m (330 ft) to a PoE++ (Power over Ethernet) 802.3bt Type 3 40 W Ethernet switch port.
  • PoE++ power injector: If you are using a non-PoE switch, a PoE++ injector needs to be added between the SharpV and the switch. The total length of the network cable that runs between the SharpV and the switch must not exceed 100 m (330 ft).
NOTE: If PoE++ power is not available, you can provide 24 V dc power using the I/O connector. For more information, see About powering the SharpV G3 using 24 V dc.

PoE++ (IEEE 802.3bt compliant) power sources can negotiate the power delivery using these two methods:

Hardware-based two-event classification
Power injectors typically (but not exclusively) use this method. Installations that use this method generally do not require any additional configuration.
Software-based LLDP classification
PoE++ switches typically (but not exclusively) use this method.
  • The switch administrator must ensure that PoE++ power is enabled in the switch configuration for the ports that are connected with a SharpV camera.
  • You might also have to enable PoE++ power delivery in addition to the LLDP classification. For example, in some switches, the 40 W of power needs to be pre-reserved for that port.
  • The LLDP classification, which might also be referred to as 802.3bt TLVs, LLDP POE, data link-layer classification, or power-over-MDI, must be enabled in the switch configuration, if applicable.
  • LLDP must be enabled for the SharpV to participate in data link layer classification which is mandatory for all Type 3 powered devices (>13.0 W). Specifically, Power via MDI Type, Length, Value (TLV) messages must be enabled. For more information, see IEEE 802.3 Clause 145.5.

Lightning protection

The SharpV includes basic lightning surge protection. PoE++ injectors, and PoE++ switches are usually equipped with basic lightning surge protection (verify hardware specifications). For installations in areas that are subject to frequent high-energy lightning surges, it is recommended to protect the network cable using one or more of the following additional protective measures:
  • A grounded metallic conduit.
  • An external surge protector that is compatible with Gigabit Ethernet (1000BT) PoE++ systems (Power-over-Ethernet; 802.3bt Type 3 40 W).
  • A shielded Ethernet cable that has a grounded RJ45 connector at the PoE++ injector or PoE++ Ethernet switch.