The SharpV camera has been released in G1, G2, and G3 hardware versions.
Part numbers
You can identify the hardware version of a SharpV using the part number on the back of the unit.
Hardware version | Part number format1 |
---|---|
SharpV G3 LTE2 | AU-V-BS850-LC-G3-0M1 |
SharpV G3 | AU-V-WS850-LC-G3-000 |
SharpV G2 | AU-V-WS850-LC-G2 |
SharpV G1 | AU-V-WS850-LC |
1 For more information on SharpV part numbers, see Specifications for the SharpV.
2 The LTE version of the SharpV G3 includes a SIM card slot, antennas for cellular communication, and GPS positioning. For more information, see About SharpV G3 LTE.
Hardware identification
- SharpV G3 with LTE
- The LTE version of the SharpV G3 includes a GPS antenna (top), cellular antennas (back), and one rubber plug covering the SIM card slot. It is available in black only.
- SharpV G3
- The SharpV G3 includes one rubber plug. The
focus and zoom are motorized. Certain units include an antenna*. The SharpV G3 is available in black or white.
* Cellular and GPS features are not available.
- SharpV G1 and G2
- The SharpV G1 and G2 units include two rubber plugs covering the manual focus and zoom controls and one additional rubber plug for a total of three. These units are available in black or white.
Power
- SharpV G3
-
- PoE++ (Power over Ethernet) 802.3bt Type 3: 27 W typical, 40 W max
- 24 V input option: 24 V dc +/-10%, 25 W typical consumption, 37 W max
- SharpV G1 and G2
-
- PoE+ 802.3at Type 2: 25.5 W typical consumption
Zoom and focus
- SharpV G3
- Motorized zoom and focus adjustment for the context and ALPR cameras. Controls are available in the portal. For more information, see Calibrating the zoom and focus for SharpV cameras.
- SharpV G1 and G2
- The SharpV includes zoom and focus adjustment
screws for the ALPR camera and the context camera. You can access the adjustment screws
by removing the rubber plugs on the bottom of the camera. A hex key is provided for
making the adjustments.NOTE: The accessory kit (AU-H-V-ACCYKIT) includes a screwdriver for the zoom and focus adjustment.
Label | Description |
---|---|
Zoom: T/W | Telephoto/wide |
Focus: F/N | Far/near |
LPR / CTX | ALPR camera/context camera |
SR / LR | Standard range/long range |
Camera range
- SharpV G3
-
S (standard) 3 m (9 ft) to 45 m (148 ft)*
* Under ideal conditions. For details, contact your Genetec representative.
- SharpV G1 and G2
-
S (standard) 2.75 m (9 ft) to 18.25 m (60 ft)
L (long range) 18.25 m (60 ft) to 35 m (115 ft)
I/O connector pinout
SharpV G3
- For information on SharpV G3 inputs and outputs, see SharpV input and output specifications.
- For information on powering the SharpV G3 through the I/O connector, see About powering the SharpV G3 using 24 V dc.
SharpV G1 and G2
I/O cable assembly pin number | SharpV G1 and G2 pinout |
---|---|
Pin #1 | Output 1 + |
Pin #2 | Output 1 - |
Pin #3 | Output 2 + |
Pin #4 | Output 2 - |
Pin #5 | Input 1 + |
Pin #6 | Input 1 - |
Pin #7 | Input 2 + |
Pin #8 | Input 2 - |
Security Center (Legacy) connection
SharpV G1 and G2 units can connect to Security Center 5.7 or earlier using the Security Center (legacy) connection.
- If the unit connects to Security Center using the LPM protocol, this option is replaced by the Security Center (LPM protocol) connection.
- SharpV G3 units can only use the Security Center (LPM protocol) connection.
The following options are available:
- This unit manages the connection to Security Center
- Use this only if the autodiscovery of the connected SharpV does not work or if you cannot manually add the SharpV to the ALPR Manager. You must enter the
Server address and Port of the server
running the ALPR Manager role. For example, if a SharpV is
connected to a WiFi router, and the camera’s IP address is then changed, the ALPR
Manager cannot detect the change automatically, so you can use this to reconnect to
the Security Center computer.IMPORTANT:
- When using this option, no failover is available if the server connection is lost.
- Avoid the following configuration situations. Correcting these situations
requires either assistance from AutoVu™
Support or the deletion and recreation of the ALPR Manager role:
- Establishing a connection using This unit manages the connection to Security Center, then clearing the check box and saving again.
- Adding the unit from Config Tool, establishing a connection, and then selecting This unit manages the connection to Security Center, and saving.
- Discovery port
- Port on which the SharpV listens for discovery requests.
This port number must match the discovery port entered on the ALPR Manager
Properties page.NOTE: When setting the discovery port, do not use port 5050 as it is reserved for the logger service.
- Control port
- Used in Security Center Config Tool when creating a new ALPR unit (SharpV) manually.