The SharpV includes two inputs and two outputs (I/Os) which can be used to trigger a license plate read on an input signal.

You can use the IOs in conjunction with Security Center to create event-to-actions so that inputs and outputs trigger or react to system events.
NOTE: For more information on how to trigger “READ NOW” actions on a SharpV, see Triggering one-time actions.
In the following example, the signal from an in-ground loop is used to trigger a gate after a plate read. To configure the SharpV I/Os to perform this function, you must create event-to-actions for license plate reads in Security Center.
Component Description
A Output signal to the gate controller from SharpV output 1 (pin #1)*
IMPORTANT: Respect the maximum output voltage (30 V) and the maximum sink current (100mA). For more information, see SharpV input and output specifications.
B Input signal from the in-ground loop to SharpV input 1 (pin #5)*
C In-ground loop (input device)
D Gate (output device)
IMPORTANT: Use the proper external relay size according to the gate motor power. For more information, refer to the Driving a relay schema.

* For information on the SharpV I/O pinout, see SharpV input and output specifications.

SharpV outputs

Driving a relay
If more than 100 mA is required, the SharpV outputs can be used to drive external relays.
IMPORTANT: Respect the maximum output voltage (30 V) and the maximum sink current (100mA). For more information, see SharpV input and output specifications.
Diagram of a SharpV output driving an external relay.
Open collector type

The SharpV outputs can be used to interface with microprocessors or other systems that have a digital input.

IMPORTANT: Respect the maximum output voltage (30 V) and the maximum sink current (100mA). For more information, see SharpV input and output specifications.
2 1 7 6 5 4 3 8 External digital input +12 V dc 470R

SharpV inputs

External output device

An external output device such as a vehicle sensor can be used to trigger license plate reads on the SharpV.

IMPORTANT: Respect the maximum output voltage (30 V) and the maximum sink current (100mA). For more information, see SharpV input and output specifications.
12 V 2 1 7 6 5 4 3 8 + - + - Vehicle sensor + - Power Relay Pull-down