The SharpV includes two inputs and outputs (I/Os). An IP67-rated cable connector plug is provided for the connection.
SharpV I/O connector pinout
I/O cable assembly pin number | SharpV pinout |
---|---|
Pin #1 | Output 1 + |
Pin #2 | Common negative for both outputs |
Pin #3 | Output 2 + |
Pin #4 | Ground for 24 V power option |
Pin #5 | Input 1 + |
Pin #6 | Common negative for both inputs |
Pin #7 | Input 2 + |
Pin #8 | 1.55 A Max @ 24 V dc +/-10% for 24 V power option |
SharpV I/O specifications
Hardware | Specification |
---|---|
Inputs | |
Number of inputs | 2 |
Input rating | 0 V dc - 30 V dc |
Guaranteed ON state threshold | 5.75 V |
Guaranteed OFF state threshold | 4.80 V |
Overvoltage protection | Included |
Reverse voltage protection | Included |
Input type | Opto-isolated, DC polarized |
Outputs | |
Number of outputs | 2 |
Output rating | 30 V / 100 mA |
On-state voltage |
Von = <1.0 V @ 2 mA
Von = <2.5 V @ 100 mA |
Overcurrent (overload) protection | Included |
Reverse voltage protection | Included |
Output type | Opto-isolated, dry |
I/O cable specifications
Hardware | Specification |
---|---|
Cable diameter |
The I/O cable assembly is compatible with cable
diameters from 4 mm (0.16 in) to 8 mm (0.31 in).
NOTE: Two different cable seals are included with the I/O cable assembly. Refer to
the manufacturer's instructions to determine which seal to install for the
diameter of cable you are using.
|
Wire gauge | The I/O cable assembly can support a maximum wire gauge of 20 AWG. The cable's voltage rating must be suitable for the SharpV I/O specifications and must conform to electrical codes in your region. |
Weather rating | The cable must be waterproof, UV resistant, and must be rated for outdoor installation in accordance with your region. |
Lightning protection
The SharpV I/O cable port includes basic lightning surge protection. For installations in areas that are subject to frequent high-energy lightning surges, it is recommended that you protect the I/O cable using one or more of the following additional protective measures:- A shielded cable with the shield grounded at the I/O device.
- An external lightning protector for I/Os that complies with the normal voltage range of the circuits to which the I/Os are connected.