Limitations in the CCURE 9000 Access Control plugin 3.9.0 - CCURE Access Control 3.9.0

CCURE 9000 Access Control Plugin Guide 3.9.0

Product
CCURE 9000 Access Control
Content type
Guides > Plugin and extension guides
Version
3.9
Release
3.9.0
ft:locale
en-US
Last updated
2025-02-25

The CCURE 9000 Access Control plugin 3.9.0 includes the following known limitations.

Issue First reported in Description
2930188 CCURE 9000 Access Control 3.6.1 When an alarm is triggered and acknowledged in Security Desk, the alarm does not reappear in the Alarm monitoring task if it is triggered again by a lesser-priority cause.
2367980 CCURE 9000 Access Control 3.6 Security Desk freezes while updating XFEvents on systems that are running the CCURE 9000 Access Control plugin and Genetec Clearance™.
Workaround: Uninstall Clearance.
2349347 CCURE 9000 Access Control 3.6 After the plugin role fails over, some hardware entities show as offline, which does not accurately reflect their current state.
Workaround: For Hardware, areas, and zones, switch Automatically synchronize when connected to ON, so that after a failover, the hardware entities are updated.
2138461 CCURE 9000 Access Control 3.5 In Security Center, alarms and events rank 1 as the highest priority and 255 as the lowest priority. In CCURE 9000, events rank 255 as the highest priority and 0 as the lowest priority.
2136876 CCURE 9000 Access Control 3.5 Antipassback and other door controller-level settings must be configured in CCURE 9000. Changes made to values in Security Center are not pushed to CCURE 9000.
128133 CCURE 9000 3.0 The Pre-Alarm Time option in the CCURE 9000 Administration Station is not supported in Security Center.
Workaround: In Security Center Config Tool, set the length of time in the Time to record before an event option in the Camera recording page of the Archiver, or in the Recording page of specific camera entities.
114152 CCURE 9000 3.0 If you are using a multi-tile view in CCURE 9000, the playback button is disabled.
Workaround: Refresh the camera tile.
113458 CCURE 9000 3.0 Access control units imported from CCURE 9000 are not included in Health statistics.
113455 CCURE 9000 3.0 The following actions are not supported with CCURE 9000 entities:
  • Temporary override unlock schedules
  • Unlock for maintenance
  • Sound buzzer, silence buzzer
  • Reset area people count
  • Forgive antipassback violation
113454 CCURE 9000 3.0 CCURE 9000 data is not included in the following reports:
  • People counting
  • Time and attendance
104008 CCURE 9000 3.0 When you unlock a door from the CCURE 9000 system using an access granted event, the lock status of the door in the door widget is not updated in Security Desk.