The CCURE Access Control plugin 3.7.0 includes the following known issues.
Issue | First reported in | Description |
---|---|---|
2930275 | CCURE Access Control 3.6.1 | In Security Desk and Config Tool, the System status task does not automatically refresh state changes for unit inputs and outputs. |
2346663 | CCURE Access Control 3.6 | When the XFEvents node is expanded in the entity browser pane, all events are listed, but the list is separated by other entities. |
2144195 | CCURE Access Control 3.5 | Sometimes door and access control entities appear as offline (red) in Security Center because the hardware was removed,
but the entity was not. This happens because the CCURE Access Control proxy service
did not empty its cache. Workaround: Restart the Proxy Service, then
synchronize the CCURE entities in Config Tool.
|
2138218 | CCURE Access Control 3.5 | The CCURE 9000 synchronized objects table is not
populated after the first automatic synchronization. Workaround: If the table remains empty after the synchronization,
click the Refresh ()
button to update it.
|