Cloud Link Roadrunner™ 3.2.2 includes the following known issues.
| Interface module | Issue | First reported in | Description |
|---|---|---|---|
| All | 5034277 | 3.2.2 | On the Storage page of the Cloud Link Roadrunner™ Portal, when you click the Delete archived and obsolete logs option, audit logs are incorrectly deleted. |
| All | 4825888 | 3.2.2 | Shunting an active special input, such as Input Tamper, Input PowerMonitor, Input BatteryFailed, or Input ACFailed, doesn't remove the warning in Security Center. |
| All | 4664224 | 3.2.2 | If a MIFARE DESFire smart card configuration is changed on any door controller by the Cloud Link Roadrunner unit, inputs can lose their state. |
| All | 4618102 | 3.2.2 | When assigning or moving existing credentials, the credentials aren't always added to the Synergis Softwire database. This occurs when the delete phase of the sync removes the credentials after they're added to the new cardholder. |
| All | 4319423 | 3.2.2 | The No entry detected event isn't sent when the Extended grant time setting configured on the door in Config Tool is greater than 59 seconds. |
| All | 4222207 | 3.2.2 | If a cardholder is denied access and another person is granted access at the same door within 60 seconds, the first cardholder is assumed to have entered the area. |
| HID | 4999423 | 3.2.2 | HID readers with firmware version 10.0.5.x and later can go offline when the
Enhanced Tap feature is enabled. Workaround: Disable the Enhanced Tap
feature on the HID reader.
|