Not all Security Center access control features are supported with the integration of ASSA ABLOY KS210 locks.
The ASSA ABLOY KS210 lock integration supports the following Security Center access
control features.
The following is the legend for some common
values found in the Supported column:
- Yes
- Feature is supported by this integration.
- Limited
- Part of the feature is not supported.
- No
- Feature is not supported by this integration.
- Online
- Feature is supported only when the interface module is connected to the Synergis unit.
- Not applicable
- Feature does not apply to this integration.
Feature group | Security Center feature | Supported |
---|---|---|
Door behavior settings (overrides the Synergis unit-wide settings) | Maintenance mode (keep door unlocked and ignore all access events) | Yes |
Standard grant time | Yes | |
Extended grant time | Yes | |
Entry time (Standard/Extended) | Not applicable | |
Door relock - options | Limited1 | |
When door is unlocked by schedule - options | Yes | |
Door held - options | Yes | |
Door forced open - options | Yes | |
Unlock schedules | Yes | |
Request to exit (REX) options | ||
Unlock on REX (On/Off) | Not applicable | |
Time to ignore REX after granting access (in seconds) | Not applicable | |
Ignore REX events while door is open (On/Off) | Not applicable | |
Time to ignore REX after door closes (in seconds) | Not applicable | |
Visitor escort and two-person rule | ||
Maximum delay between card presentation (in seconds) | No | |
Enforce two-person rule (On/Off) on Door side | No | |
Manual actions on doors in Security Desk | Manually unlock doors | Yes |
Reader shunting (activate/deactivate reader) | Yes | |
Override unlock schedules | Yes | |
Live event monitoring in Security Desk | Module running state (Online, Offline) | Yes |
AC fail | Not applicable | |
Battery fail (Low battery) | Not applicable | |
Door open/closed | Yes2 | |
Door locked/unlocked | Yes | |
Door forced open | Yes | |
Door held open for too long | Yes | |
Duress PIN | Not applicable | |
Deadbolt (Secured, Released) | No | |
Key override | No | |
Area restrictions (for secured areas) | Minimum security clearance (part of threat level management) | No |
Visitor escort rule (On/Off) | No | |
Interlock | No | |
Antipassback | ||
Hard (log and deny access on Antipassback violation) | No | |
Presence timeout (forget area presence after a certain delay) | No | |
Strict (antipassback checked on both area entrance and exit) | No | |
On schedule | No | |
Max occupancy | No | |
Global antipassback | No | |
First-person-in rule | ||
Enforce on door unlock schedule | No | |
Enforce on access rules | No | |
Elevator control | Elevators | Not applicable |
Zone management | I/O zone | No |
Hardware zone | No |
1 If the KS210 lock relocks immediately after opening, in the Door relock option, select after opening and enter a value. For example, five seconds. Selecting On close is not supported.
2 Refer to the wiring instructions included with the KS210 lock.