24-hour zones are inputs used to trigger alarms for emergency events. On DMP intrusion panels, these inputs are not associated to an area. In Security Center these inputs are associated to a single intrusion area called 24H zones.
From the DMP intrusion panel and in Security Center, 24-hour inputs are only distinguishable from
other input types by their behavior.
Intrusion detection areas for 24-hour inputs
When a DMP intrusion panel is enrolled in Security Center, a 24H zones intrusion detection area is automatically created by the Intrusion Manager role, regardless of whether the panel has 24-hour inputs or not.The running state of the 24H zones intrusion detection area follows the state of
the intrusion detection unit. If the unit is online, the area will be online, even if there
are no inputs associated to that intrusion detection area.
All 24-hour inputs of an intrusion panel are associated to the 24H zones intrusion detection area in Security Center. For a DMP intrusion panel, the following input types are considered 24-hour inputs:
- Panic
- Emergency
- Supervisory
- Arming
When the duress code is entered on a keypad, an Intrusion detection area duress event is triggered on the 24H zones intrusion detection area.