The number of incidents Genetec Mission Control™ can handle per minute depends on the number of incident types, the complexity of the incident detection rules and automation workflows, the number of active incidents, and the speed the events are generated in the system.
Genetec Mission Control™ recommended server benchmark
- System is running on recommended
Security Center server
requirements.Tip: For the Security Center system requirements, refer to the Security Center System Requirements Guide.
- Incident manager role is on the same server as SQL express and RabbitMQ (recommended).
Server benchmark
Number of incident types | Number of active incidents | Events per minute | Incident updates per minute | Incidents per minute | Connected workstations |
---|---|---|---|---|---|
100 (simple trigger1) | 40,000 (simple automation workflow2) | 270,000 (4500 events per second) |
100 | 7 | 50 |
1 Single event qualifying rule without constraints. Example: Any Person falling.
2 Single activity without condition. Example: Change description to 'New description'.
Workstation benchmark
The number of active incidents a single workstation can handle is as follows:
View in Incident monitoring task | Number of active incidents3 |
---|---|
List view | 15,000 |
Map view4 | 800 |
3 Incidents with no automation workflow.
4 Metrics based on Google Maps.
Genetec Mission Control™ high end server benchmark
The following benchmark is based on a high performance server (SV-2000 series). The values indicated here may vary depending on your actual setup:
For more information on Streamvault™ 2000 series rackmount security appliance, visit the Genetec Inc. website.
Number of incident types | Number of active incidents | Events per minute | Incident updates per minute | Incidents per minute | Connected workstations |
---|---|---|---|---|---|
100 (simple trigger1) | 75,000 (simple automation workflow2) | 270,000 (4500 events per second) |
200 | 20 | 100 |
1 Single event qualifying rule without constraints. Example: Any Person falling.
2 Single activity without condition. Example: Change description to 'New description'.