To use overtime rules in City and University parking enforcement, you need to enable overtime and configure the overtime settings in Genetec Patroller™ Config Tool.
What you should know
Procedure
- Open Genetec Patroller™ Config Tool.
-
Go to Operation > Overtime.
-
Turn on Use overtime, then configure the following:
- Auto accept overtime hits
-
Turn this on if you want Genetec Patroller™ to accept overtime hits with
no user action. After the patrol vehicle has passed through the parking
area, the operator can then review and enforce the hits.
NOTE: With this feature enabled, the operator cannot manually edit the plate read before it is accepted.
User workflow: Hit raised > Hit is verified against updated permit list > User enforces hit > Hit enforced
- Bypass overtime hit enforcement
-
Turn this off if you want Patroller users to indicate whether or
not they enforced the hit after accepting it. Turn it on to bypass
enforcement. When turned on, Patroller automatically enforces hits
after they are accepted.
User workflow: Hit raised > User accepts hit > Hit enforced
- Auto enforce overtime hits
-
Turn this on for Patroller to run in unattended mode.
Hits are automatically accepted and enforced without requiring user
interaction. Hit accept and hit reject surveys are ignored when this
option is enabled.
NOTE: The two operator functions (accepting and enforcing hits) are linked when you enable this setting.
User workflow: Hit raised > Hit enforced
- Apply overtime rule to permit holders
- Turn this on for locations where parking access can be bought for a limited period. In this configuration, if a plate is read once and is not on the selected permit list, a hit is generated. However, if it is on the list, no hit is generated on the first read. The second read determines if the time limit is exceeded and if a hit is generated. If this option is disabled, permit holders do not generate violations.
-
Click Advanced.
The Advanced overtime settings window is displayed.
-
From the Advanced overtime settings window, configure the
following:
- Link read persistence duration
- Enter the number of hours a plate read that is stored in the Patroller database is considered to be “read #1” for a particular overtime rule. The default 12 hours generally does not need to be modified. If, for example, a patrol vehicle scans the street every 12 hours, you could extend the Link read persistence duration to ensure that the “read 1” is still present for the next patrol.
-
NOTE:
- When a long-term overtime rule is configured, the Link read persistence duration field is ignored. The availability of license plate reads is controlled by the Number of days defined in the overtime rule settings in Security Center Config Tool. For more information, see Configuring long-term overtime settings.
- When using overtime rules with time range and a link persistence over 24 hours, overtime hit will not raise on different days.
- Minutes to due vehicles
- Enter the amount of time before the vehicles are due for enforcement. This value determines the Show Due functionality in Patroller. The default value is 5 minutes.
- Preferred Long Term Overtime zone
- If you have more than one Long Term Overtime zone configured in Security Center, you must type the name of the zone you want Patroller to display, because you can only enforce one zone at a time. This value is not case sensitive.
- Same position tolerance
- This is a buffer used for “Same position” overtime rules. It is the distance that Patroller considers to be a single position or parking space.
- Click Save.
-
Click Apply.
Overtime rules are now enabled and configured in Patroller.