The General settings page allows you to configure basic Genetec Patroller™ options such as the Patroller unit’s name, how users should log on,
etc.
Patroller Standalone is not connected to
Security Center, therefore for some settings
it is indicated that they are not applicable for Patroller Standalone. These settings do not appear in
Genetec Patroller™ Config Tool.
- Patroller name
- Enter the name of the Patroller unit as
you want it to be seen in Security Center
and Security Desk.
- Logon type (not applicable to Patroller Standalone)
- Select how to log on to Patroller.
- SQL Server
- The address and name of the SQL Server.
- Database name
- You can leave the default database name, or change it to whatever you want. You
can change this name at any time to create a new database.
- Use Windows authentication
- Turn on this feature if you want Patroller to connect to its database using Windows credentials.
- User ID
- The User ID to connect to the Patroller
database. This User ID was entered during Patroller installation.
- Password
- The password to connect to the Patroller
database. This password was entered during Patroller installation.
- Advanced
- Configure Advanced settings for the Patroller database.
-
- Max logout
- Set the amount of time (in hours) that a user can be logged out and
still resume their shift when logging back on. When this period has
elapsed, or if a different user logs on, the system sees this as the
start of a new shift and the data presented to the user reflects that. A
value of 0 deactivates this feature, meaning that a new shift begins
anytime a user logs in. The default logout time is 4 hours.
- Store reads for
- Set the amount of time that reads are stored in the Patroller database. Reads older than
this value are deleted from the database at the start of the next shift.
The default storage time is 96 hours.
- Store hits for
- Set the amount of time that hits are stored in the database. Hits older
than this value are deleted from the database at the start of the next
shift. The default storage time is 120 hours.
- Record search
- Set the amount of time that records (reads or hits) are searchable by
the Patroller user. Records
older than this value will no longer be searchable at the start of the
next shift. The default search time is 48 hours.
- Record display
- Set the amount of time that a record can be displayed. The default time
is 12 hours.
- Folder path
- Click browse or type the folder path where the system stores the ALPR
images, context images, and wheel images associated with overtime
enforcement. The default location is C:\Program Files
(x86)\Genetec AutoVu
6.7
\Data.
WARNING: License plate read
images are now stored directly on the file system. Image files are not encrypted because SQL Server
Express does not support FILESTREAM encryption. You can manage
access to the image folder using NTFS or a device encryption
solution such as BitLocker.
IMPORTANT:
- Ensure that the disk has enough free space to store the
database and license plate read images according to the
retention period.
- Exclude the folder path from the antivirus scan running on the
computer.
- If you change the folder path, ensure that the new folder has
read-write access authorization.
- Offload query timeout
- Define the timeout duration for the offload queries. The default timeout
is 1800 seconds.
- Extra parameters
- The string to connect to the Patroller database.
NOTE: You should
not need to configure this option since SQL is installed
automatically, or an existing SQL instance is used when you install
Patroller.
- Test connection
- Test the connection to the Patroller
database with the options selected.