Offloading allows you to transfer reads, hits, and other Genetec Patroller™ data to Security Center. Please note that if you’re running Patroller Standalone (no connection to Security Center) your data is offloaded to a local .Standalone file on the in-vehicle computer.
NOTE: Patroller Standalone is not connected to
Security Center, therefore, it is
indicated for some settings that they do not apply to Patroller
Standalone. These settings do not appear in the Patroller
Config Tool.
- Offload method
- Select your offload method:
- None
- Does not offload data.
- Local file
- You can configure Patroller to offload data to a file on the in-vehicle
computer. You can then transfer the file to Security Center.
- Offloading to Security Center
- After you have offloaded the data to a local file, you can copy the data to a USB drive using the Patroller Transfer Tool. You can then use the Patroller Transfer Tool to transfer the file to the Security Center server.
- Using Patroller Standalone
- After you have offloaded the data to a local file, you can open the Offload.xml file in an XML editor, or you can use the Patroller Transfer Tool to save the file on a USB drive and import it into your own reporting tool.
- Live transfer (not applicable to Genetec Patroller™ Standalone)
- This offload method transfers all data from the Patroller vehicle to Security Center using a wireless connection. For
example, you can offload your data at the end of a shift, when you’re in range of the
company’s wireless network. You also use this option to offload data to a network drive
rather than your local drive on the in-vehicle computer. NOTE: Please note the following about Live transfer:
- This option automatically transfers the offload data into the Offload folder under the ALPR Manager root folder. For more information about the ALPR Manager root folder, see Configuring the ALPR Manager role.
- If you try to offload without being connected to Security Center, the offload is done on your local in-vehicle computer. You can then transfer the offload data to Security Center with a USB key.
- Local offload drive
- If using Local file as your offload method, specify where on your machine the data should be saved (e.g. C:\ if you want to offload to your C drive).
- Use encryption (not applicable to Genetec Patroller™ Standalone)
- Turn on to encrypt the offloaded data. You’ll also need the Public key (not applicable to Patroller Standalone).
- Public key (not applicable to Genetec Patroller™ Standalone)
- To encrypt offload data, Patroller needs the public key from the Security Center computer. Do the following:
- On the Security Center computer, go to C:\Program Files\Genetec Security Center <your version>, and copy the OffloadPublicKey.xml file to your clipboard.
- On the Patroller computer, go to C:\Program Files\Genetec AutoVu X.Y\MobileClient, and paste the OffloadPublicKey.xml in the folder.
- In the Public key field, enter the path to the public key you just pasted to the Patroller computer (C:\Program Files\Genetec AutoVu X.Y\MobileClient\OffloadPublicKey.xml).
- Offload events
- Select the ALPR events you want to include in offloads. For example, you might choose to offload only certain types of hits to use less bandwidth.
- Include all images
- Turn on to offload all images. If this option is turned off, only images associated with a hit are included in the offloaded data.
- Incremental offload
- By default, Patroller offloads data in increments, or segments. Turn this setting off if you want to offload the full data file each time.
- Data segment size
- Specify the maximum file size of each data segment (MB) when using Incremental offload. Once the offload file reaches the size limit, a new offload file is created and the offload process continues. The default maximum file size is 1 MB.
- Force offload before exit
- Turn on to make Patroller exit commands
unavailable. The only way to close the application is to perform an offload.NOTE: This option will not work if you set Offload method and Action after offload to None.
- Action after offload
- Select the exit procedure that occurs after you have performed an offload:
- None
- Return to the application.
- Exit
- MobileServer, MobileClient, and IO.Services are exited.
- Shutdown
- If the PowerManagement.UsePowerManagement option is selected, the OffloadExit setting is automatically set to Shutdown. This option does not work with laptops; choose Exit instead.
- Delete after offload
- Turn on to delete all records of user logins, images, hotlist hits, vehicles, unit states, street blocks, tire images, cameras, and attributes after a successful offload.