Issue First reported in Description
2973973 6.6.0 If patrol vehicles using Plate link are running different BeNomad map engine versions, upper-case and lower-case character differences are not recognized as being the same street.
NOTE: Ensure that vehicles using Plate link are running the same map engine version. If using BeNomad, ensure the .glic file version matches, for example, Genetec_NAM-CAN-USA-MEX_NT_2020.2.glic.
2934025 6.6.0 When a system running Genetec Patroller™ 6.6 in Curb Sense™ mode is connected to a SharpZ3 system running SharpOS 13.4, the Genetec Patroller™ clock and the GNSS clock are sometimes offset causing bad timing/delays with overview images.
2911680 6.6.0 Updates to the MatcherSettings.xml file are not picked up by Genetec Patroller™. To resolve this issue, the system should automatically send the MatcherSettings.xml file to the correct local Genetec Patroller™ folder if the file is saved to C:\Genetec\AutoVu\RootFolder\ManualTransfer\General.
2899838 6.6.0 The SharpZ3 camera appears offline in Genetec Patroller™ but can still stream video to Genetec Patroller™.
2827986 6.6.0 The number of license plate reads shown in the Genetec Patroller™ Offload window does not match the number of reads received in the Security Center Reads task.
2821263 6.6.0 When the first character of a license plate is a number, Genetec Patroller™ converts the number to an underscore character. For example, the plate 7ABC123 is converted to _ABC123.
2802227 6.6.0 After upgrading the SharpZ3 system from SharpOS 13.3.1.12 to SharpOS 13.4.0.175, the following error is logged: Patroller Database Problem writing new data into database.
2802226 6.6.0 Genetec Patroller™ can sometimes lose connection to Security Center. The globe icon blinks red/green, then stays red.
2802197 6.6.0 After Genetec Patroller™ successfully sends evidence to Curb Sense™, Genetec Patroller™ can sometimes try to resend the evidence.
2767067 6.6.0 When both permits and overtime are selected in Genetec Patroller™, the system does not register reads downloaded from Plate link and overtime hits are not generated.
2761808 6.6.0 If many permits are associated with a permit restriction, hit detection can be delayed.
2758467 6.6.0 When the Allow popup hit feature is enabled, hits are accumulated in the background, but are not displayed in Genetec Patroller™.
2737957 6.6.0 When overview images from additional context cameras are sent from Genetec Patroller™ to Curb Sense™, the bottom of the images are cropped.