The Satel Intrusion Panel driver 5.0.0 includes the following known limitations.
Issue | Description |
---|---|
2899860 | Users from Satel Integra intrusion panels cannot be imported to Security Center. |
2899861 | Areas that are imported from Satel intrusion panels cannot be renamed in Security Center. |
2899862 | Outputs that are imported from Satel intrusion panels cannot be renamed in Security Center. |
2899863 | Inputs that are imported from Satel intrusion panels cannot be renamed in Security Center. |
2899865 | Areas are refreshed when the Satel driver launches, which causes the extension to slow down considerably. |
2899866 | Inputs are refreshed when the Satel driver launches, which causes the extension to slow down considerably. |
2899867 | Outputs are refreshed when the Satel driver launches, which causes the extension to slow down considerably. |
2899868 | Delayed arming of a Satel area from Security Center is not supported. |
2855745 | After a panel has been tampered with, it cannot be armed from Security Center. NOTE: The panel must enter and exit
from service mode before it can be armed from Security Center.
|
2861567 | Outputs cannot be polled in intervals less than five seconds. |