The Satel Intrusion Panel driver 5.0.0 includes the following known limitations.

Issue Description
2899860 Users from Satel Integra intrusion panels cannot be imported to Security Center.
2899861 Areas that are imported from Satel intrusion panels cannot be renamed in Security Center.
2899862 Outputs that are imported from Satel intrusion panels cannot be renamed in Security Center.
2899863 Inputs that are imported from Satel intrusion panels cannot be renamed in Security Center.
2899865 Areas are refreshed when the Satel driver launches, which causes the extension to slow down considerably.
2899866 Inputs are refreshed when the Satel driver launches, which causes the extension to slow down considerably.
2899867 Outputs are refreshed when the Satel driver launches, which causes the extension to slow down considerably.
2899868 Delayed arming of a Satel area from Security Center is not supported.
2855745 After a panel has been tampered with, it cannot be armed from Security Center.
NOTE: The panel must enter and exit from service mode before it can be armed from Security Center.
2861567 Outputs cannot be polled in intervals less than five seconds.