Before installing the Genetec™ Intrusion Protocol extension, you must ensure that the required ports are open on all network switch routers and firewalls, and that no other applications are using these ports.

Ports used by the Genetec™ Intrusion Protocol extension

Application Inbound Outbound Configurable Port usage
Extension role (hub) 2624   Yes Listening for incoming Genetec™ Intrusion Bridge connections.

Ports used by the Genetec™ Intrusion Bridge

Application Inbound Outbound Configurable Port usage
Genetec™ Intrusion Bridge   2624 Yes Connecting to the Genetec™ Intrusion Protocol extension.

Ports used by the Bosch Intrusion Panel driver 5.0.0

Application Inbound Outbound Configurable Port usage
Genetec™ Intrusion Bridge   7700 Yes Connecting to the Bosch panel.

Ports used by the Satel Intrusion Panel driver 5.0.0

Application Inbound Outbound Configurable Port usage
Genetec™ Intrusion Bridge   7094 Yes Connecting to the Satel panel.

Ports used by the Telenot Intrusion Panel driver 5.0.0

Application Inbound Outbound Configurable Port usage
Genetec™ Intrusion Bridge   Any* Yes Connecting to the Telenot panel.

* The outbound port is the port that you configure on your RS232/IP converter, which is required to monitor Telenot panels.