ALPR ingestion data source settings in the Third-Party ALPR plugin - Configure an ALPR ingestion service data source so that the Third-Party ALPR plugin can ingest data from your network of cloud-hosted third-party cameras. - Third-Party ALPR 5.10.11.0 - Plugin and extension guides

Genetecâ„¢ Third-Party ALPR Plugin Guide 5.10.13.0

Product
Third-Party ALPR
Content type
Guides > Plugin and extension guides
Version
5.10
Release
5.10.13.0
ft:locale
en-US
Last updated
2026-08-25

Configure an ALPR ingestion service data source so that the Third-Party ALPR plugin can ingest data from your network of cloud-hosted third-party cameras.

Setting Description
Name Select a name for the data source that identifies where license plate data is coming from.
Raise 'no data' events Set the time threshold after which a custom Security Center event is triggered if no data is received from the specified data source. For more information, refer to Creating event-to-actions.
Anonymized raw data logging Select this setting to make the data source log raw data with the license plate anonymized.
NOTE: Raw data consists of the exact and unprocessed data received from the relevant camera or API. Some private fields are still anonymized for privacy reasons.
ALPR microservice endpoint Provide the URL of the third-party system to ingest ALPR reads from.
Allow self-signed certificates Select whether the system can accept a self-signed certificate. If your system does not have a valid security certificate, you can use a self-signed certificate.
NOTE: Enable this setting in your development or quality assurance environment, but not your production environment.
Authentication type Choose to use the Basic or OpenID authentication type.
  • Basic authorization uses the Genetec web server role for authentication and authorization, making it better for on-premises deployments.
  • OAuth is more suitable for cloud deployments.
Authorization credentials Configure the connection information required by the authentication type to authorize secure access between the ingestion data source and your system.
Camera authority Select the area that displays the camera in the reads report. This setting is used to delegate camera management to another data source.