Adding Honeywell Galaxy intrusion panel inputs manually - Honeywell Galaxy intrusion panel 3.1

Honeywell Galaxy Intrusion Panel Extension Guide 3.1

Applies to
Honeywell Galaxy intrusion panel 3.1
Last updated
2022-03-09
Content type
Guides > Plugin and extension guides
Language
English
Product
Honeywell Galaxy intrusion panel
Version
3.1

If you cannot or do not want to import a panel's inputs through an MDB file, you can add them manually in Security Center.

Procedure

  1. From the Config Tool home page, open the Intrusion detection task.
  2. Select a Honeywell Galaxy intrusion panel from the entity browser and click on the Inputs tab.
  3. Click the add button () below the input list.
    Tip: You can add multiple inputs by clicking the add multiple button ().
  4. Click Apply.
  5. Select the input and enter the following information:
    Name
    The name of the input as configured in the Honeywell Galaxy intrusion panel.
    Input Num
    The number assigned to the input by the panel.
    Type
    The type of input.
    Area
    The area that the input is assigned to, as configured on the panel.
    IMPORTANT: If the Input Num, Type, and Area do not match what is configured in the panel, the extension might not behave as expected.
  6. Click Apply.

After you finish

Configure the input.