Configuring alarms and events for Honeywell Galaxy intrusion panel areas - Honeywell Galaxy intrusion panel 3.1

Honeywell Galaxy Intrusion Panel Extension Guide 3.1

Product
Honeywell Galaxy intrusion panel
Content type
Guides > Plugin and extension guides
Version
3.1
Language
English
Last updated
2022-03-09

To communicate alarms and events from Honeywell Galaxy intrusion panel areas, you must configure them in Security Center.

Procedure

  1. From the Config Tool home page, open the Intrusion detection task.
  2. Select a Honeywell Galaxy intrusion panel from the entity browser and click on the Areas tab.
  3. In the Alarms section, assign an event to action for the Default, Armed, and Disarmed panel events:
    1. Click the search button () and select a type of alarm.
    2. Click Save and close.
    3. Click Apply.
    When you click on the search button (), the list of alarms matches the list configured in the Alarms task in Config Tool.
  4. (Optional) To assign custom events for your Armed and Disarmed panel events, in the Events section, add the number of the custom event in the Custom Events field and click Apply.
    The numbers assigned to custom events are found in the Custom Events list in Config Tool.