The Industrial IoT plugin 5.2.0.0 includes the following known issues.

Issue First reported in Description
12763 Industrial IoT 5.0.3.0 In the TimeSeries widget, the Export to CSV option is not always displayed.
12751 Industrial IoT 5.0.2.0 Industrial Protocol Interface cannot be installed alongside Industrial IoT.
12451 Industrial IoT 5.0.2.0 Rules action logs have a time resolution of minimum 3 milliseconds. When rules are executed in quick succession, their order in the rules action report are randomized in this 3 milliseconds window.
9647 Industrial IoT 4.4.1.0 Device types created in plugin version 4.4.0.0 cannot be imported.
7414 Industrial IoT 4.3.3 In Security Center 5.9.1.0 or later,changing the icon in the Identity page of a device or entity can override the icon that is displayed in the entity browser.
Workaround: Change the icon in the Properties page of the device or entity.
7412 Industrial IoT 4.3.0 If you change the icons of devices or entities on a federated system, the icon is displayed as a blue cube in the Federation™ host.
7410 SNMP Manager 4.1 You can only define the data points contained in a static SNMP table by specifying their index in the table. Changes to the table size by the SNMP agent at runtime could results in an invalid data point.