You insert a key in the programming station and in the Key Programmer application, you see the message: Invalid access rule. The key cannot be encoded.

Symptom

  1. A cardholder complains that the key does not work as expected.
  2. You insert the key in the programming station.
  3. The Key Programmer shows the message "Invalid access rule. The key cannot be encoded."
    Medeco XT Key Programmer version 3.1
  4. In Config Tool, you open the plugin role's diagnostic window, and you see the message "Incompatible access rule NameOfSchedule - A schedule can cover a maximum of one time period per day. Impacted cardholders: NameOfCardholder".

Cause

A Medeco XT key can only be assigned to a single Daily or Weekly schedule that is made up of a continuous block of time. If a key is configured to use an unsupported schedule, the programming station cannot update the key. Consequently, the key's cardholder can only use the key until its validation period expires.

Solution

  • Change the schedule in the invalid access rule to either a continuous Daily or Weekly schedule.