Mercury controllers on firmware version 1.31 or earlier and Synergis IX controllers fail to enroll or go offline on Windows servers
If your Mercury controllers on firmware 1.31 or earlier and Synergis IX controllers fail to enroll on your Windows server, or go offline after a Windows upgrade, ensure that the required cipher suites are enabled. To help you troubleshoot this issue, learn about its possible causes and solutions.
Cause
The required ciphers suites aren't enabled.
Solution
Enable the required cipher suites for your integration.
The following procedure describes one of many ways to enable cipher suites. If your server
is on a Windows domain or managed by local IT, see Manage Transport Layer Security (TLS) in Windows, or contact your
IT department.
CAUTION:
Any changes to Group Policy Objects (GPOs) could alter
intentional security settings put in place by your organization. Ensure that you
understand the implications and consult your IT department before making
changes.
The cipher suites that must be enabled depend on your integration:
- Mercury LP controller integration on firmware 1.31 and earlier
- Ensure that one of the following is enabled:
- TLS_RSA_WITH_AES_256_GCM_SHA384
- TLS_RSA_WITH_AES_128_GCM_SHA256
- Mercury EP controller integration on firmware 1.29.7 and earlier
- Ensure that the following is enabled:
- TLS_RSA_WITH_AES_256_CBC_SHA
- Synergis IX controller integration
- Ensure that one of the following is enabled:
- TLS_ECDHE_RSA_WITH_AES_256_CBC_SHA384
- TLS_ECDHE_RSA_WITH_AES_128_CBC_SHA256
If you need to enable the required cipher suites on a Streamvault™ appliance, see the Streamvault™ Appliance User Guide.
- Open the Windows Local Group Policy Editor by opening the Start menu, Run, and typing gpedit.msc.
- From the left side menu, navigate to .
- Double-click SSL Cipher Suite Order.
- In the SSL Cipher Suite Order dialog box, select Not
Configured, and then click OK.NOTE: This step is required to ensure that the changes are retained after a reboot.
- Download the IIS Crypto application.
- Run the application.
- For Mercury EP integrations, configure the required Client protocols:
- From the side menu, click Schannel.
- In the Client Protocols section, select TLS 1.1.
- If you're using Microsoft® Windows Server 2022, ensure that
TLS 1.3 is cleared.
- Click Apply.
- From the side menu, click Cipher Suites.
- Click Add new cipher suite (+).
- In the Add a Cipher Suite dialog box, enter the missing cipher
suite, and then click OK.
The new cipher suite is listed.
- Repeat the previous step until all missing ciphers suites are added.
- At the bottom of the page, click Apply.
- In the Reboot is Required dialog box, click OK.
- Instead of rebooting the server, restart the Genetec Softwire Controller Host service.
If all the necessary cipher suites were added, the interfaces come back online.