The Morse Watchmans KeyWatcher Touch plugin adds custom events in Security Center. These events can be used as query filters in activity reports or to create event-to-actions.

Security Center custom event Morse Watchmans KeyWatcher Touch custom event Source entity
Cardholder Area Locker Key
Key added Add x x x x
Key returned Return x   x x
Key removed Remove x   x x
Key removed illegally - x   x x
Key replaced Replace x   x x
Key overdue Alarm: Overdue x     x
Key not taken Alarm: Not Taken x   x x
Key deleted Delete x x x x
Key removed: emergency release Remove: Emergency release x   x x
Key not returned Alarm: Not returned x   x x
Secure key return violation Warning: Return Denied - Secure Key Return Violation x   x  
Invalid key returned Alarm: Invalid Key Returned x   x  
Remove invalid key Alarm: Invalid Removed x   x  
Key reservation Reservation x x    
Reservation key not returned - x x    
Key reservation active Reservation Active x x   x
Key reservation inactive Reservation Inactive x x   x
Key returned by different user Warning: Key Return By Different User x   x x
Return - overdue key Waming: Return - Overdue Key x   x x
Slot release Alarm: Shorted Slot - Key Removed x   x  
Shorted slot Alarm: Shorted Slot     x  
Door not opened Alarm: Door Not Opened x   x  
Door left open Alarm: Door Left Open x   x  
Illegal entry Alarm: Illegal Entry     x  
Door opened Door Opened x   x  
Door closed Door Closed x   x  
Controller AC power loss Alarm: Controller AC Power Loss     x  
Controller AC power restored Alarm: Controller AC Power Restored     x  
Communication lost Alarm: Communication Loss     x  
Communication restored Alarm: Communication Recovered     x  
Message received from the locker was corrupted Alarm: Communications Bad CRC X3     x  
Controller battery fail Alarm: Controller Battery Fail     x  
Controller battery low Alarm: Controller Battery Low     x  
Controller reset complete Alarm Cancel: KW Controller Reset Complete     x  
Release door latch activated Release Door Latch Activated x   x  
User logon User Logon KeyWatcher x   x  
User duress logon Alarm: User Duress Logon x   x  
User logoff User Logoff KeyWatcher x   x  
Logon failure Warning: Logon Failure - Number on attempts by User exceeded x   x  
User not recognized in KeyWatcher system Logon Attempt Failed - User not recognized in Key Watcher System     x  
Logon attempt failed - User disabled in site Logon Attempt Failed - User ID disabled in Site x   x  
Logon attempt failed - User disabled in system Logon Attempt Failed - User disabled in System x   x  
User logon date range expired Logon Attempt Failed - User logon date range expired x   x  
User ID disabled Logon Attempt Failed - User ID Disabled x   x  
Incorrect PIN Logon Attempt Failed - Incorrect PIN entered x   x  
Alarm triggered - x x x  
Alarm cancelled by user - x x x  
Alarm cancelled by system -   x x  
Alarm cancelled by system over limit -   x x