To prepare your Sysco Neoline devices for integration with Security Center, you must configure the Sysco Neoline system to communicate with the Genetecâ„¢ Restricted Security Area Surveillance (RSA Surveillance) plugin. For specific details about configuring your devices and software, refer to the Sysco Neoline documentation.

Before you begin

  • Make sure that your Sysco Neoline system is operating as per the manufacturer's specifications.
  • Make sure that your Sysco Neoline devices and software are compatible with the RSA Surveillance plugin. For the latest compatibility information, see Supported plugins in Security Center on the Genetec TechDoc Hub.

What you should know

This task describes in a general way how the Sysco Neoline system needs to be configured for it to communicate with the plugin. For specific details about the configuration of your devices and software, refer to the Sysco Neoline documentation.

Procedure

  1. Log on to the SenseControl application.
  2. From the Dashboard, select User administration, and then create a user account with read access.
  3. Add a georeference point and set the 3D position for each radar or sensor.
  4. Add a Websocket Server node, and configure the following:
    • Enter a unique port number.
    • Set the connection timeout to 0 seconds.
    • Require users to log on.
    • Filter nodes and properties.
    • Send all nodes.
    • If you will import alarm areas as RSA zones, set the Properties option to All properties.
    CAUTION:
    Leaving all properties on can cause instability on the sensor system. So, after the alarm areas are imported in the RSA plugin role, set Properties to Documented properties.
    Sysco SenseControl application - Websocket Server configuration settings.
  5. Note the following information, as you will need it to configure the plugin later:
    • IP address of the SenseControl Websocket server
    • Port used by SenseControl Websocket server to communicate with the plugin
    • Username and password for remote access

After you finish