Before you can monitor the restricted areas secured by your tracking system in Security Center, you must add the Senstar system as a tracking system entity in Config Tool.

Before you begin

  • Confirm that the tracking system and its perimeter devices are configured and functioning properly.
  • Confirm that the plugin role is configured and communicating with the tracking system.
  • Create a georeferenced map in Security Center.

    For more information, see the Security Center Administrator Guide.

  • Ensure that enough perimeter system licenses are available in Restricted Security Area Surveillance role > Properties > Licenses.

Procedure

  1. From the Config Tool home page, open the Area view task.
  2. Click Add an entity (), and then select Tracking system.
    The Add tracking system wizard opens.
  3. On the Tracking system information page, enter the following information:
    Type
    Select Senstar.
    Name
    Enter a unique name for this tracking system.
  4. On the Communication page, enter the following information:
    IP address
    The IP address of the Senstar NMS service.
    Port
    Enter port 849 and the NMS unit ID, as defined in the manufacturer documentation.
    Connection type
    Select either No TLS, TLS 1.2, or TLS 1.3. For TLS 1.2 and 1.3, you must have copied the certificate into the correct folder on the RSA server.
  5. Click Refresh connection status () to connect.
  6. When the connection status turns Online (), click Next page ().
  7. On the Specific configuration page, configure the following:
    Alarm classification enabled on senstar (NMS)
    This information is configured on the Senstar NMS side. You must select the option only if it is also selected on Senstar NMS.
  8. On the RSA configuration page, enter the following information:
    Events
    Turn on the custom events you want to monitor for this tracking system.
    NOTE: You can modify this later on the Properties page of the tracking system.
  9. Click Finish.
    The tracking system and its devices are listed in the Area view entity tree.
  10. If you defined Redundant Sensor Units on Senstar, you must configure the Senstar tracking system in Security Center:
    1. In the Area view task, select the Senstar tracking system, and click the Properties tab.
    2. In the Specific configuration section, define which sensor units correspond to each Redundant Sensor Unit, and then click Apply.

After you finish