The SALTO Virtual Network plugin 3.3.0 includes the following known limitations.
Issue | First reported in | Description |
---|---|---|
941660 | 3.0 |
The warning message Door locks should normally be
configured appears at the bottom of the Door Hardware
tab because the door lock is unassigned. Security Center expects a door to lock, but the
locks are managed in SALTO.
Workaround:
You can ignore this
message.
|
941406 | 3.0 | When the SALTO Virtual Network role restarts, it displays monitored events from the past minute. These events appear again in the Monitoring task of Security Desk and as a result, you see duplicate events. |
937959 | 3.0 | If you create an empty schedule in SALTO ProAccess SPACE, during import, the schedule is ignored by Security Center. |
937956 | 3.0 | Access rules for SALTO can only grant access. Denying access is not supported for SALTO. Deny rules that are created in Security Center are not exported to SALTO ProAccess SPACE. |
937955 | 3.0 |
SALTO ProAccess SPACE does not allow a cardholder to
have multiple access rules on the same door with overlapping schedules. Workaround: Use cardholder groups or areas to manage overlapping
schedules.
|
937954 | 3.0 | Access rules created in Security Center overwrite the rules created in SALTO ProAccess SPACE. |
937947 | 3.0 | In SALTO, a cardholder schedule (timetable) can only contain eight periods, where a period is a unique block of time, regardless of the day of the week. |
937945 | 3.0 | The Genetecâ„¢ Server that runs the plugin role and the SALTO SHIP server must have matching computer dates, times, and time zone. If there is a mismatch, events are not reported accurately and the system does not sync properly. |
937062 | 3.0 |
When doors that are not part of a SALTO Virtual Network zone are imported into Security Center, they are added to the SALTO Virtual Network plugin's default area (zone). You cannot
remove these doors from the SALTO Virtual Network plugin
area, but you can add them to other areas.
Workaround:
After
the systems have already been synchronized: copy the door to another area by
pressing CTRL while clicking the door, and then drag the door to the desired
area.
Workaround:
Before
you import SALTO doors into Security Center
for the first time, use SALTO ProAccess SPACE to
add the new doors to zones.
|
930312 | 3.0 | In the Cardholder configuration report, the Last access column displays unknown, even when there was access. |
2315396 | 3.1 | Events related to entities are received by the plugin even if it doesn't have access to the entity's partition. |
2294859 | 3.1 | A maximum of three authorization codes per cardholder can be imported from SALTO ProAccess SPACE to Security Center. |
2136041 | 3.1 | Changing the hardware configuration of a SALTO door prevents it from receiving events. |
2042615 | 3.1 | All mobile credentials created in SALTO ProAccess SPACE are deleted in Security Center when upgrading to version 3.1 of the plugin. |
2042406 | 3.1 | Following an upgrade to version 3.1 of SALTO Virtual Network plugin, you must deactivate and then reactivate the plugin role to connect to the SALTO SHIP server. |
2025472 | 3.1 | Following an upgrade to version 3.1 of SALTO Virtual Network plugin, the plugin will synchronize with SALTO ProAccess SPACE. If changes were made in SALTO ProAccess SPACE since the last synchronization, those modifications will override the values in Security Center. |
1992917 | 3.1 | Cardholder credentials that are set to expire in SALTO ProAccess SPACE at a specific time, will expire at the 10-minute mark prior. For example, if the credential is set to expire at 12:56, it will actually expire at 12:50. |
1960060 | 3.1 | If a cardholder credential is set to disable after first use, a read on a SALTO lock is not taken into account. |
1956403 | 3.1 | If a custom data type created by SALTO is manually
deleted, the associated custom field will not work as expected. Workaround: Delete the associated custom field, restart the plugin, and then perform a
synchronization to recreate the custom data type and custom field.
|
2315668 | 3.2 | Events are not written to the access control cards of SALTO Hospitality guests,
as they are not imported as Security Center
cardholders. Workaround: Collect the events using the SALTO portable
programming device (PPD) and import the results into SALTO ProAccess SPACE so they can be accessed by Security Center.
|
2314783 | 3.2 | When the plugin role is offline, hotel suite entities are displayed as being online in the entity browser. |