Configuring parking facilities - Security Center 5.12

Security Center Administrator Guide 5.12

Product
Security Center
Content type
Guides > Administrator guides
Version
5.12
Language
English
Last updated
2024-09-13

After you have created a parking facility in Security Center, you must define the facility for your parking scenario by creating sectors and rows for the license plate collection route.

Before you begin

Create the parking facility.

What you should know

The parking space of a parking facility is divided into sectors (or levels in the case of a parking garage) for ease of reference. Each sector contains x number of rows, and each row contains x number of spaces. You can configure Genetec Patroller™ to trigger an alarm (sound or warning message) if the reads collected during your sweep of a row exceed the space count for that row.

The route is the license plate collection route followed by the MLPI units responsible for collecting the plates for the inventory. The route is downloaded by the patrol vehicles and handheld devices assigned to this parking facility.
NOTE: Only one route may be defined per parking facility, but each MLPI device can start its sweeping round at a different point in the route. The route forms a closed circuit.

Procedure

  1. From the Config Tool homepage, click ALPR > Parking facilities, and select the facility you want to configure.
  2. Click the Properties tab.
  3. From the ALPR Manager list, select the ALPR Manager that will create and manage the license plate inventory for the selected parking facility.

    Only offloads from MLPI patrol vehicles managed by the same ALPR Manager are used to build the inventory for this parking facility. An MLPI Patroller offload can include the vehicle inventory for multiple parking facilities, but only the reads tagged for this parking facility are used to build the inventory.

  4. Under Configuration, click Create () to add a new sector.

    The parking space of a parking facility is divided into sectors (or levels in the case of a parking garage) for ease of reference. Each sector contains x number of rows.

  5. Enter the Name of the sector, or level if you have a parking garage.
  6. Enter the Number of rows in the sector.
  7. Click OK.

    The sector you created appears under the Configuration and Route sections.

  8. To add rows to a sector, do the following:
    1. Under Configuration, mouseover the sector name, and then click the Create ().
    2. Enter the Number of rows to add, and then click OK > Apply.
  9. (Optional) To rename a sector, do the following:
    1. Under Configuration, click the sector name you want to rename, and then click Edit ().
    2. Enter the new name, and then click OK > Apply.
  10. (Optional) To delete a sector, click the sector name you want to delete under Configuration, and then click Delete () > Apply.
  11. To change the order of sectors and rows in the route, click the up () and down () arrows under Route.

After you finish

You must set the Read retention period of the ALPR Manager according to the period of time you want to keep your license plate inventories in the database. The default retention period is 90 days.