For optimal performance, configure the settings of your access control units after they have been added in Security Center.

What you should know

Security Center provides default settings. However, it is recommended that you carefully configure each entity to get the best results.

HID and Synergis™ units have different capabilities, therefore different configuration requirements. For information about configuration requirements for Synergis units, see Preparing to configure the Synergis unit.

Tip: To save time configuring your access control units, you can configure one, and then copy the settings they have in common to the rest of the units.

Procedure

  1. Open the Access control task, and click the Roles and units view.
  2. Select the access control unit (HID or Synergis) to configure, and click the Properties tab.
  3. In the Properties tab, do one of the following:
  4. Configure the wiring of entities controlled by this unit:
  5. Click the Peripherals tab of the access control unit.
  6. Configure the properties of the peripherals attached to the unit, such as the reader type and the input contact type.
    Validate your wiring configuration and give meaningful names to the devices if necessary.
  7. (HID units only) Select the Synchronization tab, and choose how often you want to synchronize the unit:
    Automatically
    This is the recommended setting.

    Any configuration change is sent to the access control unit 15 seconds after the change is saved by the Config Tool, Security Center Web Client, Genetec Web App, or Security Desk. Only configurations that affect that particular unit are sent.

    Daily
    The unit is synchronized daily, at the specified times.
    Every
    The unit is synchronized weekly, at the specified day and time.
    Manual
    The unit is only synchronized when you click Synchronize now.

    Make sure you synchronize the unit before the configuration expires.

  8. Click Apply.