You can hide alarms from users who do not have permission to view the alarm source entity by setting HideAlarmsWithoutSource to true in the Advanced settings page under .
You need the Modify advanced settings privilege to view the Advanced
settings page under .
The alarm source is the entity that triggered the alarm. It is the event source if the
alarm is triggered by an event-to-action, or the user, if the alarm is triggered manually. The
alarm source is not displayed if the user who receives the alarm does not have permission to
view the source entity. This happens when the source entity belongs to a partition to which
the user does not have access.
The new setting immediately applies to all new alarms. If existing alarms are already
displayed in an Alarm monitoring task, you must close and reopen the task
to refresh and filter out the alarms with blank source entities.