You can view the I/O configurations (controlled access points, doors, and elevators) of access control units, using the I/O configuration report.

What you should know

For example, you can use the I/O configuration report to search for a specific door, and see how the access through each door side is configured (REX, readers, I/O modules, and so on).

Procedure

  1. Open the I/O configuration task.
  2. Set up the query filters for your report. Choose one or more of the following filters:
    Access point
    Restrict the search to specific access points (input, output, and reader).
    Devices
    Select the devices to investigate.
    Location
    Specify the areas where the devices are located.
  3. Click Generate report.
    The input and output configurations of the selected access control units are listed in the report pane.