The camera driver pack 12.1.0 for Security Center includes the following resolved issues.
Solution/Unit | Issue | Description |
---|---|---|
Axis | 3476807 | After upgrading to Driver Pack 11.2, the Wiper command is missing from the Commands menu for a camera in the Security Desk Monitoring task. |
Bosch | 3525414 | Depending on the connection, setting the encryption for a Bosch CHAVE unit to In transit and at rest with continuous recording, results in either an encryption error or no live and playback video. |
Bosch | 3525526 | In Security Desk, Edge recording event states are not accurate and show the opposite state of the actual Edge recording. For example, the state displays "Stopped" when it should display "Started". |
Bosch | 3256397 | In Security Desk, when using the iris control that manually opens or closes the iris in the PTZ widget, the iris control behaves the opposite of the expected action. |
Bosch | 3475473 | Security Center RCP+ metadata streams for cameras using the Bosch Common Platform 13 (CPP13) and later are not enabled by default. |
Bosch | 3257495 | In the Config Tool Video task, automatically generating a password for a Bosch unit fails because the "@" and " ' " characters are not supported by Bosch cameras. |
Bosch | 3482697 | In Config Tool, changes made to the frame rate and bit rate for a Bosch unit revert to the default settings after you reboot the Directory. |
Bosch | 3476162 | In Security Desk, Edge recordings transferred from Bosch Generic Plus cameras using the H.265 codec do not play. |
Hanwha | 3482683 | Nothing to transfer error in Config Tool when attempting to transfer video from Hanwha PNM-9322VQP and PNM-C12083RVD edge devices with video files on the SD card. |
Hanwha | 3476590 | After upgrading to Security Center Driver Pack 11.1 or later, SPE-1620 camera encoders go offline if the camera is set to use the MJPEG codec. |
Hanwha | 3512502 | In the Config Tool Video task, attempting to
Retrieve from edge with a Hanwha camera as the source
results in one of the following error messages:
|
i-PRO | 3469331 | In the Config Tool Video task, the Color tab does not appear for i-PRO cameras. |
i-PRO | 3469986 | In the i-PRO unit web page, when setting the Image capture mode to "Quad streams", the camera entities are fixed rather than PTZ entities in Security Desk and Config Tool. |