The following issues are resolved in Camera Driver Pack 13.0.0 for Security Center.
| Solution/Unit | Issue | Description |
|---|---|---|
| Avigilon | 3870925 | Avigilon H5 Dual Head camera models 6.0C-H5DH-D1-IR and 10.0C-H5DH-D1-IR use two Security Center camera licenses instead of one license. |
| Axis | 3836935 | In Config Tool, the Image rotation option is no longer available on the camera Hardware page for Axis cameras. |
| Bosch | 3622393 | For CPP13+ cameras, SRTP is requested even when encryption isn’t set to In transit and at rest. |
| Bosch | 3839565 | Certain Bosch cameras that use CPP13 and newer extensions crash in a loop after being enrolled in Security Center. This happened because the order of audio profiles didn’t match the order expected by Security Center. |
| Bosch | 3841835 | After an Archiver role fails over to the secondary server, the second stream stops working for some Bosch cameras. |
| Hanwha | 3822136 | WiseStream quality settings aren’t applied to cameras that only support WiseStream II. |
| Hanwha | 3840696 | When the input pin state changes on some Hanwha cameras, Security Desk doesn’t report the event. |
| Hanwha | 3840718 | WiseStream quality settings aren’t applied to cameras that use SUNAPI protocol version 2.6.3. |
| i-PRO | 3689891 | When Broadcast mode is enabled for i-PRO cameras, they aren’t discoverable in the Config Tool Unit Enrollment tool. |
| i-PRO | 3775853 | When the people counting operation schedule is turned off, the i-PRO camera goes offline. |
| i-PRO | 3821964 | When i-PRO or Panasonic units are configured with RTSP over TCP or RTSP over HTTP, the units show intermittent transmission loss. |
| ONVIF | 3805503 | The IP address in the playback request is different from the IP address used by Security Center to connect to the unit. As a result, playback fails for Generic Plus cameras in Security Center. |
| Video | 3731425 | When using an offline device and network share is unavailable, the GenetecVideoUnitControl32.exe process increases memory consumption over time. |
| Video | 3773320 | Video streams from dual-stream FLIR cameras are created in the wrong order. As a result, the thermal feature applies to the wrong video stream. |
| Video | 3774695 | When restarting the standby Archiver server, all multicast cameras lose recordings for a few seconds. |
| Video | 3821665 | Video isn’t recorded on the standby Archiver server when Redundant archiving and Recording modes are configured in Config Tool. |
| Video | 3960738 | Some cameras stopped recording after Security Center Driver Pack software was upgraded to 12.3.0. After restarting the Archiver role, the cameras resumed recording. |
| Vivotek | 3729302 | When some Genetec™ Protocol cameras, such as Vivotek IP9191- HT-v2, reconnect to the Archiver, the metadata overlay isn’t displayed or recorded. |