Maximum number of units supported in Security Center 5.13 Unit Assistant role batch operations - To ensure optimal performance, don’t exceed the maximum number of video and access control units supported in Security Center 5.13 Unit Assistant role (UAR) batch operations. - Security Center 5.13

Security Center System Requirements Guide 5.13

Product
Security Center
Content type
System requirements
Version
5.13
ft:locale
en-US
Last updated
2025-02-03

To ensure optimal performance, don’t exceed the maximum number of video and access control units supported in Security Center 5.13 Unit Assistant role (UAR) batch operations.

Some operations, like password change and certificate updates for a camera or an access control unit, require the unit to be reconnected. Be sure to schedule these operations during non-critical periods.

IMPORTANT: Monitor the server CPU usage if normal usage is already high to ensure that UAR operation doesn’t introduce undesirable impacts.

The maximum number of units supported by each server type in Security Center 5.13 is as follows:

Server Type Recommended High-performance
Directory & UAR Passwords Certificates Passwords Certificates
  • Batch of 10,000 units
  • CPU usage increased over 80% during operation
  • No impact on system
Not tested. The numbers are expected to be similar to those of high-performance servers.
  • Batch of 10,000 units
  • Low CPU usage increase
  • No impact on system
Video:
  • Batch of 1,000 units
  • Low CPU usage increase
  • No impact on system
Access control:
  • Batch of 100 units
  • Low CPU usage increase
  • No impact on system
Archiver and UAR Agents Same as maximum number of units recommended for Archivers Same as maximum number of units recommended for Archivers