After generating a report, the results of your query are listed in the report pane. This section lists the columns available for the Hardware inventory task.
- Unit
- Name of the unit.
- Unit type
- Type of unit (Access control, Intrusion detection, ALPR, or Video).
- Manufacturer
- Manufacturer of the unit.
- Product type
- Model of the unit.
- Role
- Role that manages the unit.
- Firmware version
- Firmware version installed on the unit.
- IP address
- IP address of the unit or computer.
- Physical address
- The MAC address of the equipment's network interface.
- Time zone
- Time zone of the unit.
- User
- The user name used to connect to the unit.
- Password strength
- Strength of the password on the unit. When you hover over the password strength value, a tooltip gives you more information. "Unknown" is shown for federated units. Intrusion detection units are not supported by this feature.
- Authentication scheme
- Indicates the type of authentication being used by the camera unit, such as basic, digest, anonymous, or third party. If the unit suddenly requests to connect using a less secure authentication scheme, the Archiver rejects communication and the camera goes offline. For example, the Archiver expects the camera to be using digest authentication, but the camera tries to connect using basic authentication. The connection is rejected and the camera goes offline.
- Security protocol
- The security protocol used by the Access Manager (TLS, Wiegand).
- Upgrade status
- Status of the firmware upgrade (None, Scheduled, Started, Completed, or Failed).
- Next upgrade
- The date for the next upgrade based on the units' Delay upgrade until setting.
- Reason for upgrade failure
- Reason that the firmware upgrade failed (for example, Unit offline, or Firmware upgrade path not respected).
- Proposed firmware version
- The recommended version required for the upgrade. This column is blank for federated units.
- Proposed firmware description
- The description of the
required upgrade. This column is blank for federated units.
- Up to date
- No firmware upgrade is necessary.
- Optional
- The firmware upgrade is not urgent.
- Recommended
- The firmware upgrade is recommended.
- Security vulnerability
- The firmware upgrade fixes a security vulnerability issue and is highly recommended.
NOTE: This information is only available if Genetec™ Update Service is running. - State
- State of the unit (Online, Offline, Warning).
- Platform version
- Current platform (cumulative security rollup) version installed on the unit.
- Proposed platform version
- The recommended version required for the upgrade. This column is blank for federated units.
- Proposed platform description
- The description of the required upgrade. This column is blank for
federated units.
- Up to date
- No platform upgrade is necessary.
- Optional
- The platform upgrade is not urgent.
- Recommended
- The platform upgrade is recommended.
- Security vulnerability
- The platform upgrade fixes a security vulnerability issue and is highly recommended.
NOTE: This information is only available if Genetec™ Update Service is running. - Password
- Password shown as a series of '*'.
If you have the View/export unit passwords privilege, click to show the password.
Right click the Password column to copy your password to the clipboard.
- Last successful password update
- Time of the last password update.
- Last password change result
- Indicates whether or not the password change was successful.
- Parent
- The direct parent of the interface module or downstream panels. If the direct parent is the access control unit, only the Parent unit column is filled.
- Parent unit
- The parent access control unit.
- Secure mode
- (HID units only) Indicates whether secure mode is enabled or disabled.
- Custom fields
- Predefined custom fields for the entity. The columns only appear if custom fields are defined for the entity and were made visible to you when they were created or last configured.