After generating a report, the results of your query are listed in the report pane. This section lists the columns available for the relevant reporting task.
- Unit
- Name of the unit.
- Unit type
- Type of unit (Access control, Intrusion detection, LPR, or Video).
- Product type
- Model of the unit.
- Role
- Role that manages the unit.
- Firmware version
- Firmware version installed on the unit that generated the event.
- Security protocol
- The security protocol used by the access manager (TLS, Wiegand).
- Upgrade status
- Status of the firmware upgrade (None, Scheduled, Started, Completed, or Failed).
- Proposed firmware version
- The recommended version required for the upgrade. This column is blank for federated units.
- Authentication scheme
- Indicates the type of authentication being used by the camera unit, such as basic, digest, anonymous, or third party. If the unit suddenly requests to connect using a less secure authentication scheme, the Archiver rejects communication and the camera goes offline. For example, the Archiver expects the camera to be using digest authentication, but the camera tries to connect using basic authentication. The connection is rejected and the camera goes offline.
- Proposed firmware description
- The description of the
required upgrade. This column is blank for federated units.
- Up to date
- No firmware upgrade is necessary.
- Optional
- The firmware upgrade is not urgent.
- Recommended
- The firmware upgrade is recommended.
- Security vulnerability
- The firmware upgrade fixes a security vulnerability issue and is highly recommended.
NOTE: This information is only available if Genetec™ Update Service is running. - IP address
- IP address of the unit or computer that generated the event.
- Password
- Strength of the password on the unit. When you hover over the password strength value, a tooltip indicates if the manufacturer default password is being used. "Unknown" is shown for federated units.
- State
- State of the unit (Online, Offline, Warning).
- Time zone
- Time zone of the unit.
- Platform version
- Current platform (cumulative security rollup) version installed on the unit.
- Manufacturer
- Manufacturer of the unit.
- Next upgrade
- The date for the next upgrade based on the units' Delay upgrade until setting.
- Physical address
- The MAC address of the equipment's network interface.
- Proposed platform description
- The description of the required upgrade. This column is blank for
federated units.
- Up to date
- No platform upgrade is necessary.
- Optional
- The platform upgrade is not urgent.
- Recommended
- The platform upgrade is recommended.
- Security vulnerability
- The platform upgrade fixes a security vulnerability issue and is highly recommended.
NOTE: This information is only available if Genetec™ Update Service is running. - Proposed platform version
- The recommended version required for the upgrade. This column is blank for federated units.
- Reason for upgrade failure
- Reason that the firmware upgrade failed (for example, Unit offline, or Firmware upgrade path not respected).
- Secure mode
- (HID units only) Indicates whether secure mode enabled or disabled.
- User
- The user name used to connect to the unit.
- Custom fields
- The predefined custom fields for the entity. The columns only appear if custom fields are defined for the entity, and if the custom fields were made visible to you when they were created or last configured.