Configuring auto tracking for Panasonic units - Security Center 5.10.1.0

Security Center Video Unit Configuration Guide 5.10.1.0

Product
Security Center
Content type
Guides > User guides
Version
5.10
Release
5.10.1.0
Language
English
Last updated
2021-10-18

To use auto tracking with Panasonic units in Security Center, the settings must be configured in Config Tool.

Procedure

  1. From the Video task in Config Tool, select the video unit to configure.
  2. Click the Properties tab.
  3. Expand the Self return menu and configure the following options:
    Seek to preset
    Specifies a preset that the unit will seek to before resuming auto tracking when Self return is ON.
    Self return
    Turn this option ON to have the unit resume auto tracking after it loses the tracking target, or a manual PTZ action is performed.
    Self return timer
    Specifies how long (in seconds) the camera will take to resume auto tracking when Self return is ON.
  4. Expand the Auto tracking menu and specify the Camera height in meters.
    For more information on how to measure this value correctly, see your Panasonic documentation.