When you attach the WV-SPN6R481 RS-485 output unit to a WV-SPN631 or WV-SPN611 camera,
you must configure the RS-485 serial port on the camera's web page.
Before you begin
Install the WV-SPNR481 output unit on the back of your camera. For more information,
see your Sony documentation.
Procedure
-
Open the web page for the camera that has the WV-SPN481 attached (WV-SPN631 or
WV-SPN63).
-
Click Setup > Extension unit, then click the Back
unit tab.
-
Enter the following settings:
- RS485 transmission
- On
- Communication method
- 4-line
- Baud rate
- 9600bps
- Data bit
- 8bit
- Parity check
- None
- Protocol
- Pelco D or Pelco P
- Unit address
- 01 (for Pelco D) or 02 (for Pelco P)
-
Add the unit in Security Center.