The following additional configuration steps are required for some of your units to work in Security Center.

MJPEG multi-streaming
Multi-streaming in MJPEG is supported on certain i-PRO cameras in Security Center. In the Video tab of i-PRO camera entities in Config Tool, the Quality setting must be the same for both video streams, and can only be configured from stream 1.
Edge analytics for i-PRO WJ-NT314 encoders
To use edge analytics with i-PRO WJ-NT314 encoders, it must be configured for each active channel using the unit’s web page.
I/O pin configuration
i-PRO units DG-NS202, WV-NS954, WV-NW964, WV-NP502, WV-SP508, WV-NW502S and DG-NW502S do not have a hardwired pin configuration. The input and output pins cannot be configured through the web page for these units, and other S series and X series units, because Security Center will enforce the following configuration.
NOTE: i-PRO pin types other than input/output, such as auxiliary pins, are not supported in Security Center.
Pin # i-PRO description Security Center pin configuration
1 Alarm In IN
2 Alarm In/Alarm Out OUT
3 Alarm In/Auxiliary Out IN
4 Ground Ground