After you attach a WV-SPN6R481 RS-485 output unit to a WV-SPN631 or WV-SPN611 camera, you must configure a RS-485 serial port on the camera's web page.

Before you begin

Install the WV-SPNR481 output unit on the back of your camera. For more information, see your i-PRO documentation.

Procedure

  1. Open the web page for the camera that has the WV-SPN481 attached (WV-SPN631 or WV-SPN63).
  2. Click Setup > Extension unit and then click the Back unit tab.
  3. Enter the following settings:
    RS485 transmission
    On
    Communication method
    4-line
    Baud rate
    9600bps
    Data bit
    8bit
    Parity check
    None
    Protocol
    Pelco D or Pelco P
    Unit address
    01 (for Pelco D) or 02 (for Pelco P)