Additional steps required for integrating i-PRO units - Security Center 5.12.2.0

Security Center Video Unit Configuration Guide 5.12.2.0

Product
Security Center
Content type
Guides > User guides
Version
5.12
Release
5.12.2.0
Language
English
Last updated
2024-06-12

The following additional configuration steps are required for some of your units to work in Security Center.

MJPEG multi-streaming
Multi-streaming in MJPEG is supported on certain I-PRO cameras in Security Center. In the Video tab of I-PRO camera entities in Config Tool, the Quality setting must be the same for both video streams, and can only be configured from stream 1.
Edge analytics for i-PRO WJ-NT314 encoders
To use edge analytics with i-PRO WJ-NT314 encoders, it must be configured for each active channel using the unit’s web page.
I/O pin configuration
The following units do not have a hardwired pin configuration:
  • DG-NS202
  • WV-NS954
  • WV-NW964
  • WV-NP502
  • WV-SP508
  • WV-NW502S
  • DG-NW502S

The input and output pins cannot be configured through the web page for these units, and other S-series and X-series units. This is because Security Center enforces the configuration in the table below.

NOTE: i-PRO pin types other than input/output, such as auxiliary pins, are not supported in Security Center.
Pin # i-PRO description Security Center pin configuration
1 Alarm In IN
2 Alarm In/Alarm Out OUT
3 Alarm In/Auxiliary Out IN
4 Ground Ground