Configuring VIQS for i-PRO units - Security Center 5.12.2.0

Security Center Video Unit Configuration Guide 5.12.2.0

Product
Security Center
Content type
Guides > User guides
Version
5.12
Release
5.12.2.0
Language
English
Last updated
2024-06-12

To use Variable Image Quality on Specified areas (VIQS) with some i-PRO units in Security Center, the feature must be configured in Config Tool.

Procedure

  1. From the Video task in Config Tool, select the camera to configure.
  2. Click the Hardware tab.
  3. Set H.264 VIQS to ON.
  4. Next to the H.264 VIQS setting, click VIQS window.
  5. To re-size the camera view area, do one of the following:
    • In the Size and position section, enter the X, Y, W, and H coordinates.

      X is the top-left pixel, Y is the bottom-left pixel, W is the top-right pixel, and H is the bottom-right pixel.

    • Drag the green zone to the size that you want.
  6. Click OK.
  7. Select ON beside Stream 1 or Stream 2 to apply the new VIQS area.