To use PTZ controls for Digital Barriers units in Security Center, you must configure Serial Pass-Thru on the EdgeVis encoder and associate the serial port in Config Tool.
Before you begin
Procedure
To configure Serial Pass-Thru on the unit:
- On the EdgeVis encoder, open the Settings.
- Ensure that PTZ is connected to the serial port.
- In PTZ settings, set the Protocol to None.
-
Enable Serial Pass-Thru and set the following values. These
values can change depending on the serial PTZ motor connected to the encoder. For
example:
- Set Serial port to RS232.
- Set Baud rate to 9600.
To configure serial PTZ in Security Center:
- From the Video task in Config Tool, select the unit to configure.
- Click the Hardware tab and enable PTZ.
- Select the correct Protocol from the drop-down list. For example, Pelco D.
- Set the Serial port to the one associated with the unit.
- Set the PTZ address to 1. This value can change depending on the serial PTZ motor.
- Click Apply.