Note the following when using Pelco Sarix units in Security Center:
- The video quality settings of the secondary stream depend on the primary stream. To change the video settings of the second stream, you must configure the primary stream video settings as needed.
- Motion detection settings depend on the resolution of the primary stream. If the resolution is changed, the Archiver resends the motion detection settings to the unit.
- The quality setting on the camera’s Video page might have no effect on the unit.
- The grayed-out fields on the camera’s Video page, frame rate and resolution, might not display the values configured on the unit.
- The maximum frame rate available changes depending on the bit rate and the resolution set on the Video page.
PTZ preset tours for Pelco Sarix Spectra HD units
PTZ preset tours must be named “Endura X” using the unit’s web page where X represents the pattern number in Security Center. For example, a tour named “Endura 1” in the unit’s web page is available as Pattern 1 in the Security Desk Patterns menu.