The following additional configuration steps are required for some of your units to work in Security Center.
- Stream resolutions for ONVIF units
- When you add an ONVIF compliant video unit in Security Center using the All
Product type (the full driver), the resolutions that are
available for all the streams of the video unit are received in Security Center, and are
available for all the streams in the Video tab of the camera. When
there are dependencies between video streams, the resolutions that are not available for a
specific stream are not hidden.
If the camera does not support the resolution you select, the closest available resolution is used by the ONVIF driver. As a result, the video might stream at a slightly different resolution than the one you select. To prevent this, you can find out which resolutions are supported for the camera from its specification sheet.